Manufacturers of annunciators, fire alarm panels, and visual signal systems since 1930 |
|||||
|
SpecificationsThis page contains specifications for the following product types:
GRAPHIC ANNUNCIATOR SPECIFICATIONGraphic Method GP-2 The display panel shall be a white image on gray (appears black) acrylic. The Led wiring shall be neatly harnessed to designated terminal blocks located in the annunciator backbox. A clear front pane shall render the image tamperproof. The LEDs are not visible until illuminated. The manufacturer shall submit drawings for approval prior to fabrication. The annunciator shall be Underwriters Laboratories listed. The annunciator shall be manufactured by the H.R. Kirkland Co. or approved equal. Graphic Method GP-3 The annunciator enclosure shall be constructed of cold rolled steel with welded and ground seams for a finished appearance. The backbox shall be finished with a black powder coating. The annunciator door shall have a concealed piano hinge and shall be finished in a black powder coating, or stainless steel as directed by the engineer. The door shall be secured by a key lock with no other fasteners visible. All switches shall be mounted in the door trim. The display panel shall be a full color acrylic laminate designed for LEDs only. The lamination shall consist of a UV coating, followed by a full color image and then a 1/8" acrylic backing. The Led wiring shall be neatly harnessed to designated terminal blocks located in the annunciator backbox. The LEDs shall protrude through the acrylic, making the LEDs visible at all times. A clear front pane shall render the LEDs and the image tamperproof. The manufacturer shall submit drawings for approval prior to fabrication. The graphic annunciator shall be Underwriters Laboratories listed. The annunciator shall be manufactured by the H.R. Kirkland Co. or approved equal. Graphic Method - GP4 The annunciator enclosure shall be constructed of cold rolled steel with welded and ground seams for a finished appearance. The backbox shall be finished with a black powder coating. The annunciator door shall have a concealed piano hinge and shall be finished in a black powder coating, or stainless steel as directed by the engineer. The door shall be secured by a key lock with no other fasteners visible. The display shall consist of reversed printed polycarbonate lexan laminated to aluminum, with a full color image. The LED and switch wiring shall be neatly harnessed to designated terminal blocks located in the annunciator backbox. The manufacturer shall submit drawings for approval prior to fabrication. The annunciator shall be Underwriters Laboratories listed. The annunciator shall be manufactured by the H.R. Kirkland Co. or approved equal. Graphic Method GP-5 The annunciator enclosure shall be constructed of cold rolled steel with welded and ground seams for a finished appearance. The backbox shall be finished with a black powder coating. The annunciator door shall have a concealed piano hinge and shall be finished in a black powder coating or stainless steel as directed by the engineer. The door shall be secured by a key lock with no other fasteners visible. The display shall consist of reversed printed polycarbonate lexan laminated to aluminum, with a full color image. The zone annunciation shall be backlighted areas utilizing incandescent lamps. The illuminated and non-illuminated areas shall have the same appearance when in a normal condition. The lamp wiring shall be neatly harnessed to designated terminal blocks located in the annunciator backbox. The manufacturer shall submit drawings for approval prior to fabrication. The annunciator shall be manufactured by the H.R. Kirkland Co., or approved equal. Graphic Method GP-6 The graphic display shall be a black image on clear anodized aluminum or stainless steel. The graphic display can also include colors. The LED wiring shall be neatly harnessed to designated terminal blocks located in the annunciator backbox. The LEDs shall protrude through the aluminum or stainless steel making the LEDs visible at all times. A clear front pane shall render the LEDs and the image tamperproof. The manufacturer shall submit drawings for approval prior to fabrication. The graphic annunciator shall be Underwriters Laboratories listed. The annunciator shall be manufactured by the H.R. Kirkland Co., or approved equal. DIRECTORY ANNUNCIATOR SPECIFICATIONThe annunciator enclosure shall be constructed of cold rolled steel with welded and ground seams for a finished appearance. The backbox shall be finished with a black powder coating. The annunciator door shall have a concealed stainless steel piano hinge and shall be finished in a black powder coating or stainless steel as directed by the engineer. The door shall be secured by a key lock with no other fastener visible. All key switches shall be mounted in the door trim. The display shall be a black image on a white background. Each tabular zone shall be annunciated by means of a single light emitting diode (LED). The LEDs shall be neatly harnessed to designated terminal blocks located in the annunciator backbox. A clear front pane shall render the LEDs and the image tamperproof. The graphic annunciator shall be Underwriters Laboratories listed. The annunciator shall be manufactured by the H.R. Kirkland Co. or approved equal. BACKLIGHTED WINDOW ANNUNCIATOR SPECIFICATION The annunciator enclosure shall be constructed of cold rolled steel with welded and ground seams for a finished appearance. The backbox shall be finished with a black powder coating. The annunciator door shall have a concealed stainless steel piano hinge and shall be finished in a black powder coating or stainless steel as directed by the engineer. The door shall be secured by a key lock with no other fastener visible. The annunciator will have dual lamps per zone and black nomenclature on a white background. The lamp wiring shall be neatly harnessed to designated terminal blocks located in the annunciator backbox. The annunciator shall be manufactured by the H.R. Kirkland Company or an approved equal. EXTERIOR ANNUNCIATOR SPECIFICATIONThe annunciator enclosure shall be constructed of cold rolled steel with welded and ground seams and finished with an exterior powder paint The door shall be constructed of brushed stainless steel with a concealed stainless steel hinge. The door will have a gasketed minimum 3/16" polycarbonate viewing pane. A minimum of (5) stainless steel screws shall fasten the door against the box gasket. Tamperproof head screws shall be used where required. Ventilation of the interior must be provided. The display shall be silkscreened on an anodized aluminum face with UV protection paints. Alarm LEDs shall have a brightness minimum of 600mcd. and be visible in full sunlight. Where required, a Nema 4 key operated Lamptest Switch shall be provided. The annunciator shall be UL listed and CSFM listed (in California). These listings shall be for a complete annunciator unit. The annunciator shall be manufactured by the H.R. Kirkland Company, Inc. GRAPHIC MAP SPECIFICATIONInterior Graphic Map The graphic map shall be a full color image printed on the reverse side of a 10 mil. Polycarbonate Lexan. The standard background is white, with other colors available upon request. The printed image is laminated to a 1/8" rigid backing with a removable adhesive for future replacement. The graphic map shall be secured in a black (standard) anodized aluminum frame and mounted with a concealed security hanging system to prevent any unauthorized removal. The location of the FACP, main graphic map and other graphic maps shall be shown in red with "YOU ARE HERE" printed in red. Detection devices, nomenclature, building detail shall be color coded as specified by the engineer. The graphic map shall be manufactured by the H. R. Kirkland Co. or approved equal. Exterior Graphic Map The graphic map shall be a black screened printed image on 1/8" clear anodized aluminum, or optional 16 gauge stainless steel. The graphic display can also include colors. The location of the FACP, main graphic map and other graphic maps shall be shown in red with "YOU ARE HERE" printed in red. The graphic map is designed to be screw held to a exterior wall. The graphic map shall have four .25" dia. holes, one in each corner, for mounting. The graphic map shall be manufactured by the H. R. Kirkland Co. or approved equal. FSCS ANNUNCIATOR SPECIFICATIONFIRE FIGHTERS' SMOKE CONTROL STATION SPECIFICATION The FSCS panel shall be UUKL listed and conform to NFPA-92A guidelines. The enclosure shall be constructed of cold rolled steel with welded and ground seams and finished with a black powder textured finish. The annunciator door shall have a concealed stainless steel piano hinge and the door shall be finished with a black powder textured finish or brushed stainless steel as directed by the engineer. The door shall be fastened with a key lock with no other fasteners visible. The graphic display shall consist of a lamination of an aluminum substrate with a reverse printed polycarbonate overlay. The graphic must have full color capacity to show different colors for supply, exhaust, and pressurization. A velvet texture finish must be applied to the polycarbonate face to eliminate glare. LEDs shall protrude through the laminate for 180 degrees visibility. They shall be wired to designated terminals for interface with customer's remote controllers. AHU Switches must be UL recognized components with a minimum rating of 24 VDC/AC, 1amp. They shall be wired to designated terminals for interface with customer's remote controllers. The panel must include a Key Enable Switch and a Lamptest Switch. REMOTE ALARM INDICATOR SPECIFICATIONRemote Alarm Indicator The remote alarm indicator shall consist of a red encapsulated LED mounted on a stainless steel single gang switchplate labeled "Remote Alarm Indicator". The unit will operate at 24VDC. The remote alarm indicator shall be Underwriters Laboratories listed and manufactured by the H.R. Kirkland Co. or approved equal. OPTIONS SPECIFICATIONLamp Test : Common Trouble : Audible Alert : Power On Light : Stainless Steel Door :
|
||||
|
|||||